Skip to main content

Official Journal of the Italian Society of Orthopaedics and Traumatology

Table 3 Comparison of complications of both groups

From: Surgical fixation of displaced midshaft clavicle fractures: elastic intramedullary nailing versus precontoured plating

Complications

Precontoured plating group (%)

Antegrade elastic nailing group (%)

p value

Infection

2 (6.25)

1 (3.03)

0.62

Implant failure

0 (0.0)

1 (3.03)

0.41

Wound dehiscence

3 (9.37)

0 (0.0)

0.046

Hypertrophic scar

4 (12.50)

0 (0.0)

0.04

Refracture after implant removal

3 (9.37)

0 (0.0)

0.046

Nonunion

0 (0.0)

1 (3.03)

0.41

Major revision surgeries

2 (6.25)

1 (3.03)

0.62