Skip to main content

Official Journal of the Italian Society of Orthopaedics and Traumatology

Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature

Abstract

Background

Flexor tendon rupture is a rare but major complication associated with volar plate fixation of distal radius fractures.

Materials and methods

We performed a systematic review to evaluate the demographics, clinical profile, treatment and outcome of flexor tendon rupture following volar plate fixation of distal radius fracture. Electronic searches of the MEDLINE, EMBASE, and Cochrane databases for systematic reviews and conference proceedings were performed. Studies were included if they reported flexor tendon rupture (partial or complete) as a complication of distal radius fracture plating (all levels of evidence).

Result

Our search yielded 21 studies. There were 12 case reports and 9 clinical studies. A total of 47 cases were reported. There were 11 males and 23 females (n = 16 studies). The mean age was 61 years old (range 30–85). The median interval between the surgery and flexor tendon rupture was 9 months (interquartile range, 6–26 months). Twenty-nine plates were locking and 15 were nonlocking (n = 20 studies). FPL was the most commonly ruptured tendon (n = 27 cases, 57 %), with FDP to index finger being the second most common (n = 7 cases, 15 %). Palmaris longus tendon graft and primary end-to-end repair were the most common surgical methods used in cases of FPL tendon rupture.

Conclusion

Flexor tendon rupture is a recognised complication of volar plating of distal radius fracture. Positioning of the plate proximal to the “watershed” line and early removal of the plate in cases with plate prominence or warning symptoms can reduce the risk of this complication.

Introduction

Distal radius fractures are common orthopaedic injuries comprising 8–17 % of all extremity fractures and as many as 72 % of all forearm fractures [14], with an incidence of 26 per 10,000 person-years [5, 6]. Internal fixation with volar locking plates is becoming an increasingly popular technique for management of displaced and/or unstable distal radius fractures [5, 79]. This technique has the theoretical advantage of reducing tendon irritation, a complication associated with dorsal plate fixation [5].

However, a risk of flexor tendon irritation is associated with volar internal fixation [7, 1012]. Soong et al. [13] reported flexor tendon irritation as the most common late complication, affecting 4.3 % of patients in their series. Several authors have described flexor tendon complications (i.e. partial or complete rupture, flexor tenosynovitis) following volar plating of distal radius fractures [10, 1421]. The likely contributing factor is tendon wear over the edge of a prominent plate [8, 11, 17, 2224].

The objective of this study was to search the literature and determine the demographics, clinical profile, treatment method (type of plate) and outcome of flexor tendon rupture following volar plate fixation of distal radius fracture. To our knowledge this is the most comprehensive review of flexor tendon injury associated with volar plate fixation in the English language literature.

Materials and method

In November 2011, an electronic search of MEDLINE (1950–present) (via PubMed) and EMBASE was performed. The Cochrane Database of Systematic Reviews (CDSR) and the conference proceedings of 2011 for the Australian Orthopaedic Association (AOA), American Academy of Orthopaedic Surgeons (AAOS), British Orthopaedic Association (BOA), and Canadian Orthopaedic Association (COA) were also searched electronically. The search terms used were as follows: “flexor tendon rupture”, “radius fracture”, “plate”, “internal fixation” and “complication”. Reference sections of all accessed papers were searched for any undetected studies. English language restriction was applied. The studies were shortlisted for inclusion if they pertained to flexor tendon complications after volar plate fixation of distal radius fractures. The abstracts of the shortlisted studies were then reviewed and selected abstracts were considered for the full text review. Studies were included if they reported flexor tendon rupture (partial or complete) as a complication of distal radius fracture plating (all levels of evidence). When a study was selected, the following data were extracted: patient age, sex, interval between the operation and flexor tendon rupture, type of plate used, patients’ symptoms, cause of rupture from the authors’ perspective, treatment and outcome.

Statistical analysis was performed with SPSS (version 16; SPSS, Chicago, IL, USA). Studies that were included for analysis contained individual patient data or summary data with means and/or ranges of demographics. Simple descriptive statistics and frequency analyses were performed on multiple variables. The data are presented as median and interquartile ranges when they are not normally distributed.

Results

We found 21 studies reporting flexor tendon rupture as a complication of volar plating of distal radius fracture (Table 1). There were 12 case reports and 9 clinical studies (level III evidence) in which the flexor tendon rupture was reported as part of the study. Most of the reports were published after 2006 (77 %). A total of 47 cases were reported. There were 11 males and 23 females (n = 16 studies). The mean age of these patients was 61 years old (range 30–85). The age distribution of the patients is shown in Fig. 1. The median interval between the surgery and flexor tendon rupture was 9 months (n = 39, interquartile range, 6–26 months) (Fig. 2). Flexor tendon rupture was reported as early as 3 months [21] and as late as 10 years after volar plating [25]. Twenty-nine plates were locking and 15 were nonlocking (n = 20 studies). Flexor pollicis longus (FPL) was the most commonly ruptured tendon (n = 27 cases, 57 %) with the flexor digitorum profundus (FDP) to the index finger being the second most common (n = 7 cases, 15 %). Two or more flexor tendon ruptures occurred in 5 cases (10 %).

Table 1 Literature review showing cases of flexor tendon rupture following volar plate fixation of distal radius fracture
Fig. 1
figure 1

Bar chart demonstrating the age distribution of the patients with flexor tendon rupture following volar plate fixation of distal radius fracture

Fig. 2
figure 2

Box plot of the interval between the surgery and flexor tendon rupture

Patients presented symptoms including an inability to flex the interphalangeal joint of the affected phalanx (Fig. 3) associated with pain and a rubbing sensation with movement [12, 22, 2628], sometimes preceded by volar, radial-sided wrist pain [16, 22, 26], volar wrist swelling, and a pop or clicking sensation [17, 29]. The causes of flexor tendon rupture were excessive distal placement of the plate [10, 17, 18, 20, 22], a prominent distal edge (initial lift-off or as a result of fracture collapse) [12, 1517, 28, 29], palmarly protruding screws [8, 21, 29], and dorsal malunion of the distal radius [21, 25].

Fig. 3
figure 3

Seventy-five-year-old male with FPL and FDP to index finger ruptures following volar plating of distal radius fracture

Table 2 shows the details of the treatment for flexor tendon rupture after distal radius volar plating (n = 32). Palmaris longus tendon graft and primary end-to-end repair were the most common modes of management in cases of FPL tendon rupture. A few reports presented the detailed outcome of surgical treatment for flexor tendon rupture [12, 1416, 22]. Out of 8 cases who had operative treatment of the FPL rupture and documented the postoperative range of movement of the thumb interphalangeal joint, only 2 cases achieved a full range of movement (one after end-to-end repair, and one following palmaris longus tendon transfer) [12, 1416, 22].

Table 2 Systematic review of management of flexor tendon rupture after distal radius volar plating

Case example

A 75-year-old right-handed farmer sustained bilateral comminuted intra-articular distal radial fractures following a fall from a utility vehicle. He underwent open reduction and internal fixation (ORIF) of both distal radius fractures using volar fixed-angle locking plates (Synthes, Paoli, PA, USA). Six months postoperatively, he was referred to the senior author with a 4-week history of inability to flex the interphalangeal joint of the right thumb and a 1-week history of inability to flex the distal interphalangeal joint of the index finger. There were no relevant risk factors in his medical or pharmaceutical history that predisposed him to tendon rupture, and he was a nonsmoker. The patient consented to publication of his case.

Examination revealed an inability to flex the interphalangeal joint of the right thumb and distal interphalangeal joint of the right index finger. No other deficits were noted. The surgical scar was well healed.

The X-ray showed a united fracture in a satisfactory position. Review of the immediate postoperative X-ray showed the plate was prominent volarward, with some lift-off (Fig. 4). An MRI scan confirmed the FPL rupture (Fig. 5).

Fig. 4
figure 4

Lateral X-ray showing a slightly prominent distal edge of the plate

Fig. 5
figure 5

MRI showing FPL rupture (white arrow) and close proximity of the flexor tendon to the volar plate (MRI performed before FDP to index finger rupture)

The patient was taken to surgery for immediate exploration to address the tendon ruptures. A midpalmar approach was utilised and extended distally to the carpal tunnel. Complete ruptures of the FPL and FDP to index finger were noted. The proximal stump of the FDP was retracted approximately 4–5 cm. Both tendons were substantially frayed and were thickened and synovitic throughout (Fig. 6). There was gross flexor synovitis at the level of the wrist. The plate was removed and flexor tenosynovectomy performed. Direct end-to-end repair of the FDP tendon was performed. The FPL tendon was repaired using the ipsilateral palmaris longus tendon graft. The carpal tunnel was decompressed.

Fig. 6
figure 6

Intraoperative picture showing the frayed ends of the ruptured FDP and FPL

At the 14-month follow-up visit, he had full flexion of the interphalangeal joint of his right thumb. The patient had full passive flexion but no active flexion of the distal interphalangeal joint of the right index finger (Fig. 7). The active right wrist range of movement was 20° flexion, 20° extension, 15° of ulnar deviation, and 20° of radial deviation. The range of movement of the left wrist was 35° flexion, 35° extension, 30° of ulnar deviation, and 30° of radial deviation.

Fig. 7
figure 7

Functional outcome at the 14-month follow-up

The grip strength was 23 kg on the right and 32 kg on the left (Jamar hand dynamometer, North Coast Medical, Morgan Hill, CA, USA). The right index finger strength was 2 kg and the left index finger strength was 10 kg. The Disabilities of the Arm, Shoulder and Hand (DASH) [30] score was 8.8. Wrightington Wrist Function Score was 13 for the right wrist and 8 for the left wrist (range 8–32, with 8 being the best possible score) [31].

Discussion

Volar fixed-angle plating of distal radius fractures was developed as an alternative to dorsal plate fixation [8, 22, 29]. The perceived advantages of volar plating include a familiar and straightforward surgical approach [15, 32], a theoretical advantage in reducing the complication of tendon attrition due to an absence of flexor tendon–bone intimacy [5], the use of a thicker and stronger implant to better resist load [33], and the lack of a need for routine plate removal [5].

Flexor tendon rupture is a major complication after volar plating of distal radius fractures, and our review of the literature shows 47 reported cases. This likely represents only a portion of the real number. This review demonstrates that flexor tendon rupture can occur with various plate designs, including the new-generation volar locking plates [23, 26]. Surgeons should be aware of this complication. Advising and monitoring the patient are recommended. Fifty percent of the reported cases in the literature occurred within 6–26 months after the operation. This signifies that, at the last follow-up visit, it is essential for patients to have the warning symptoms of flexor tendon irritation [34] explained to them and to be advised to see the surgeon as soon as they appear.

Our systematic review shows that more than one-third of the population (37 %) who are reported to have a flexor tendon rupture are between 60 and 70 years old, and women are affected almost twice as often (female to male ratio: 23/11). This can be explained by a higher incidence of distal radius fracture amongst women secondary to osteoporosis with increasing age [6]. The decrease in the tensile properties of the tendon with age may also make it more susceptible to attritional wear against the prominent plate edge [35]. The incidence of distal radius fracture also increases with age. However, as shown in this review, the incidence of flexor tendon rupture tends to decrease after the age of 70, which could be because distal radius fractures are probably managed by alternative treatment options (i.e. closed reduction, pinning) with increasing age, and therefore fewer complications are reported in the literature in this group [6].

The pathogenesis of flexor tendon rupture after volar plating of distal radius fracture is multi-factorial and includes: excessive distal placement of the plate [11, 17, 18], prominent distal edge of the plate [12, 16, 17, 29, 36], prominent screw heads [8, 21], inbuilt malreduction, incorrect plate usage [10, 16], fracture collapse [17], tendinopathy for any reason (i.e. steroid use) [17], and iatrogenic injury [16]. Plate positioning has been suggested to be one of the main contributing factors to flexor tendon irritation after volar plating of distal radius fractures [8, 22]. The “watershed” line is a transverse ridge that lies distal to the pronator quadratus muscle and is located within 2 mm of the joint line on the ulnar side of the radius, 10–15 mm from the articular surface on the radial side of the bone [37]. A volar plate that is placed distal to the watershed line can potentially impinge on the traversing flexor tendons, resulting in irritation or rupture (Fig. 8) [5, 37]. In a recent cadaveric study, Tanaka et al. showed that at 30° or 60° of wrist extension, contact pressure between the distal plate edge and the FPL tendon significantly increased when the distal plate edge was placed distal to the watershed line compared with when it was placed proximal to or at the watershed line. In the authors’ case example, the prominent distal edge of the plate was the likely cause of tendon rupture. Even though the plate was placed proximal to the watershed line, it was still prominent volarward, and likely reflected an inbuilt malreduction of the fracture as well as the inbuilt plate features. We believe that the use of a low-profile plate designed for more proximal placement could have decreased the possibility of this complication.

Fig. 8
figure 8

Schematic presentation of the watershed line and flexor tendon impingement over a prominent distal plate edge. PQ pronator quadratus, FT flexor tendon

Various strategies have been suggested to minimise the chance of flexor tendon attrition following volar plate fixation of distal radius fractures [5, 24]. These include placement of the plate on or proximal to the watershed line [5, 37], repair of the pronator quadratus muscle, and early removal of the plate. However, correct positioning of a volar plate for fixation of a distal radial fracture is dictated in part by the fracture pattern, the plate design and the manufacturers’ recommendations [27], and the surgical experience of the operator. In practice, placement of a plate that conforms to the volar anatomy of the distal radius proximal to the “watershed” line may not always be possible [16]. For example, sometimes the plate has to be placed very distally to provide a subchondral buttress to the palmar aspect of the articular surface or to stabilize very distal fracture types [8]. Ideally, these situations should be avoided by choosing a suitable implant design and preoperative planning. If the plate has to be seated more distally, then close monitoring of these patients postoperatively and removal of the plate at the first sign of flexor tendon irritation should be considered [16, 21, 23]. Our experience of FPL and FDP to index finger ruptures occurring 3 weeks apart shows that it is probably essential to react quickly to these complaints and intervene before complete tendon rupture follows [23].

The pronator quadratus muscle covers the volar surface of the distal radius and provides protection for the flexor tendons from deeper structures such as prominent hardware [10, 17]. However, repair of the pronator quadratus muscle may not always be the solution to the issue of flexor tendon attrition, as the quality of muscle is not always achievable or optimal [32]. Pronator quadratus muscle was not repaired in the authors’ case, which may have contributed to flexor tendinitis and rupture.

The systematic review in this study has some limitations. The main body of the literature from which the information was extracted does not have a high quality of evidence (level III and IV studies). In many instances, not all of the details of the cases were reported (i.e. demographics, type of plate, management of complication, outcome), which limits the number of extractable variables and the quality of analysis.

Flexor tendon rupture is an uncommon yet serious complication of volar plate fixation of distal radius fracture that exists despite recent advances in plate design. Appropriate plate selection and careful surgical technique are necessary to prevent this complication. Patient consent should ideally include this potential complication given its implications, and patients should be advised at follow-up to report any increase in pain, crepitus or change in thumb or finger motion. Surgeons should be aware of this complication and react appropriately to prevent possible complete rupture of tendons.

References

  1. Pogue DJ, Viegas SF, Patterson RM, Peterson PD, Jenkins DK, Sweo TD, Hokanson JA (1990) Effects of distal radius fracture malunion on wrist joint mechanics. J Hand Surg Am 15:721–727

    Article  CAS  PubMed  Google Scholar 

  2. Nana AD, Joshi A, Lichtman DM (2005) Plating of the distal radius. J Am Acad Orthop Surg 13:159–171

    PubMed  Google Scholar 

  3. Hirahara H, Neale PG, Lin YT, Cooney WP, An KN (2003) Kinematic and torque-related effects of dorsally angulated distal radius fractures and the distal radial ulnar joint. J Hand Surg Am 28:614–621

    Article  PubMed  Google Scholar 

  4. Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg Am 28:951–958

    Article  PubMed  Google Scholar 

  5. Orbay JL, Touhami A (2006) Current concepts in volar fixed-angle fixation of unstable distal radius fractures. Clin Orthop Relat Res 445:58–67

    PubMed  Google Scholar 

  6. Brogren E, Petranek M, Atroshi I (2007) Incidence and characteristics of distal radius fractures in a southern Swedish region. BMC Musculoskelet Disord 8:48

    Article  PubMed Central  PubMed  Google Scholar 

  7. Rozental TD, Blazar PE, Franko OI, Chacko AT, Earp BE, Day CS (2009) Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial. J Bone Jt Surg Am 91:1837–1846

    Article  Google Scholar 

  8. Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21:316–322

    Article  PubMed  Google Scholar 

  9. Smith DW, Henry MH (2005) Volar fixed-angle plating of the distal radius. J Am Acad Orthop Surg 13:28–36

    PubMed  Google Scholar 

  10. Soong M, Earp BE, Bishop G, Leung A, Blazar P (2011) Volar locking plate implant prominence and flexor tendon rupture. J Bone Jt Surg Am 93:328–335

    Article  Google Scholar 

  11. Casaletto JA, Machin D, Leung R, Brown DJ (2009) Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur Vol 34:471–474

    Article  CAS  PubMed  Google Scholar 

  12. Valbuena SE, Cogswell LK, Baraziol R, Valenti P (2010) Rupture of flexor tendon following volar plate of distal radius fracture. Report of five cases. Chir Main 29:109–113

    Article  CAS  PubMed  Google Scholar 

  13. Soong M, van Leerdam R, Guitton TG, Got C, Katarincic J, Ring D (2011) Fracture of the distal radius: risk factors for complications after locked volar plate fixation. J Hand Surg Am 36:3–9

    Article  PubMed  Google Scholar 

  14. Nunley JA, Rowan PR (1999) Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surg Am 24:1279–1280

    Article  CAS  PubMed  Google Scholar 

  15. Koo SC, Ho ST (2006) Delayed rupture of flexor pollicis longus tendon after volar plating of the distal radius. Hand Surg 11:67–70

    Article  PubMed  Google Scholar 

  16. Duncan SF, Weiland AJ (2007) Delayed rupture of the flexor pollicis longus tendon after routine volar placement of a T-plate on the distal radius. Am J Orthop (Belle Mead NJ) 36:669–670

    Google Scholar 

  17. Bell JS, Wollstein R, Citron ND (1998) Rupture of flexor pollicis longus tendon: a complication of volar plating of the distal radius. J Bone Jt Surg Br 80:225–226

    Article  CAS  Google Scholar 

  18. Fuller DJ (1973) The Ellis plate operation for Smith’s fracture. J Bone Jt Surg Br 55:173–178

    CAS  Google Scholar 

  19. Yamazaki H, Hattori Y, Doi K (2008) Delayed rupture of flexor tendons caused by protrusion of a screw head of a volar plate for distal radius fracture: a case report. Hand Surg 13:27–9

    Google Scholar 

  20. Minegishi H, Dohi O, An S, Sato H (2011) Treatment of unstable distal radius fractures with the volar locking plate. Ups J Med Sci 116:280–284

    Article  PubMed Central  PubMed  Google Scholar 

  21. Drobetz H, Kutscha-Lissberg E (2003) Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 27:1–6

    CAS  PubMed Central  PubMed  Google Scholar 

  22. Cross AW, Schmidt CC (2008) Flexor tendon injuries following locked volar plating of distal radius fractures. J Hand Surg Am 33:164–167

    Article  PubMed  Google Scholar 

  23. Brown EN, Lifchez SD (2011) Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture: pronator quadratus plate coverage may not adequately protect tendons. Eplasty 11:e43

    PubMed Central  PubMed  Google Scholar 

  24. Tanaka Y, Aoki M, Izumi T, Fujimiya M, Yamashita T, Imai T (2011) Effect of distal radius volar plate position on contact pressure between the flexor pollicis longus tendon and the distal plate edge. J Hand Surg Am 36:1790–1797

    Article  PubMed  Google Scholar 

  25. Monda MK, Ellis A, Karmani S (2010) Late rupture of flexor pollicis longus tendon 10 years after volar buttress plate fixation of a distal radius fracture: a case report. Acta Orthop Belg 76:549–551

    PubMed  Google Scholar 

  26. Lifchez SD (2010) Flexor pollicis longus tendon rupture after volar plating of a distal radius fracture. Plast Reconstr Surg 125:21e–23e

    Article  CAS  PubMed  Google Scholar 

  27. Klug RA, Press CM, Gonzalez MH (2007) Rupture of the flexor pollicis longus tendon after volar fixed-angle plating of a distal radius fracture: a case report. J Hand Surg Am 32:984–988

    Article  PubMed  Google Scholar 

  28. Rampoldi M, Marsico S (2007) Complications of volar plating of distal radius fractures. Acta Orthop Belg 73:714–719

    PubMed  Google Scholar 

  29. Adham MN, Porembski M, Adham C (2009) Flexor tendon problems after volar plate fixation of distal radius fractures. Hand (N Y) 4:406–409

    Article  Google Scholar 

  30. Hudak PL, Amadio PC, Bombardier C (1996) Development of an upper extremity outcome measure: the DASH (disabilities of the arm, shoulder and hand) [corrected]. The Upper Extremity Collaborative Group (UECG). Am J Ind Med 29:602–608

    Article  CAS  PubMed  Google Scholar 

  31. Van Den Abbeele KL, Loh YC, Stanley JK, Trail IA (1998) Early results of a modified Brunelli procedure for scapholunate instability. J Hand Surg Br 23:258–261

    Article  Google Scholar 

  32. Douthit JD (2005) Volar plating of dorsally comminuted fractures of the distal radius: a 6-year study. Am J Orthop (Belle Mead NJ) 34:140–147

    Google Scholar 

  33. Osada D, Viegas SF, Shah MA, Morris RP, Patterson RM (2003) Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. J Hand Surg Am 28:94–104

    Article  PubMed  Google Scholar 

  34. Tada K, Ikeda K, Shigemoto K, Suganuma S, Tsuchiya H (2011) Prevention of flexor pollicis longus tendon rupture after volar plate fixation of distal radius fractures. Hand Surg 16:271–275

    Article  PubMed  Google Scholar 

  35. Dudhia J, Scott CM, Draper ER, Heinegard D, Pitsillides AA, Smith RK (2007) Aging enhances a mechanically-induced reduction in tendon strength by an active process involving matrix metalloproteinase activity. Aging Cell 6:547–556

    Article  CAS  PubMed  Google Scholar 

  36. Yu YR, Makhni MC, Tabrizi S, Rozental TD, Mundanthanam G, Day CS (2011) Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. J Hand Surg Am 36:1135–1141

    Article  PubMed  Google Scholar 

  37. Berglund LM, Messer TM (2009) Complications of volar plate fixation for managing distal radius fractures. J Am Acad Orthop Surg 17:369–377

    PubMed  Google Scholar 

  38. Figl M, Weninger P, Jurkowitsch J, Hofbauer M, Schauer J, Leixnering M (2010) Unstable distal radius fractures in the elderly patient—volar fixed-angle plate osteosynthesis prevents secondary loss of reduction. J Trauma 68:992–998

    PubMed  Google Scholar 

Download references

Acknowledgments

We are grateful to Michael Falkenberg for his comments on this paper during its preparation.

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Prue P. A. Keith.

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.

Reprints and permissions

About this article

Cite this article

Asadollahi, S., Keith, P.P.A. Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature. J Orthopaed Traumatol 14, 227–234 (2013). https://doi.org/10.1007/s10195-013-0245-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10195-013-0245-z

Keywords