Table 1 Comparing the distribution of maximal principal stress on the fixation bolt between groups

From: Finite element analysis of coronoid prostheses with different fixation methods in the treatment of comminuted coronoid process fracture

Group

Flexion at 30° (MPa)

Flexion at 90° (MPa)

Flexion at 130° (MPa)

Double 2.0-mm bolt

124.03 ± 10.11

66.83 ± 4.72

51.86 ± 4.36

Double 2.5-mm bolt

62.24 ± 5.29

50.80 ± 4.93

37.15 ± 4.99

Single 4.0-mm bolt

75.91 ± 5.83

54.18 ± 4.95

43.90 ± 5.10

Single 4.5-mm bolt

59.25 ± 4.51

20.08 ± 3.77

10.35 ± 3.10