Skip to main content

Official Journal of the Italian Society of Orthopaedics and Traumatology

Table 2 Detailed MRI protocols

From: MR arthrography: correlation between anatomic intraarticular variants of the long head of the biceps tendon (long head biceps tendon) and superior labral anterior to posterior (SLAP) lesions

Multiplanar (coronal, axial, and sagittal plane) T1-weighted spin-echo sequences with isotropic voxel: repetition time (RT) 9.5 ms, echo time (ET) 4.7 ms, flip angle (FA) 7°, matrix 320 × 307 pixels, 0.8 × 0.8 mm pixel size, number of signal averages (NSA) 1, thickness 0.54 mm; RT 500 ms, ET 12 ms, thickness 3.5–4 mm

Oblique coronal and sagittal T1-weighted turbo spin-echo sequences (TSE T1): RT 500 ms, ET 18 ms, FA 90°, matrix 384 × 307 pixels, 0.8 × 0.8 mm pixel size, NSA 1, thickness 3.5–4 mm

Coronal fat-saturated PD/T2-weighted (dual) fast spin-echo sequences (FSE PD/T2 FAT SAT): RT 4000 ms, ET 10/80 ms, FA 90°, matrix 230 × 256 pixels, 0.8 × 0.8 mm pixel size, NSA 1, thickness 3.5–4 mm

  1. The field of view (FOV) was variable from 16 to 20 cm