Skip to main content

Official Journal of the Italian Society of Orthopaedics and Traumatology

Table 3 Postoperative radiographic measurements

From: Functional and radiographical results of asymmetrically reconstructed total hip arthroplasty in patients with bilateral dysplastic arthritic hips with one hip Crowe II–III and the other Crowe IV: a retrospective cohort study

Parameter

H group

A group

p value

V-COR (mm)

30.6 ± 5.8 (22.2–44.5)

14.0 ± 4.3 (7.0–21.1)

 < 0.001

V-shift (mm)

18.1 ± 7.6 (5.0–31.5)

2.8 ± 4.0 (−2.5 to 10.6)

 < 0.001

H-COR (mm)

30.0 ± 5.5 (21.7–41.3)

23.0 ± 2.3 (20.0–27.6)

 < 0.001

H-shift (mm)

7.9 ± 5.3 (−1.2 to 19.3)

−0.3 ± 2.7 (−5.1 to 5.3)

 < 0.001

Inclination (degree)

38.4 ± 6.5 (29.0–49.5)

37.4 ± 6.8 (27.0–53.3)

0.648

ALA (mm)

50.5 ± 8.1 (32.9–66.0)

50.5 ± 4.8 (39.8–61.8)

0.993

ALA ratio

1.02 ± 0.20 (0.60–1.52)

1.11 ± 0.15 (0.85–1.44)

0.160

LLD (mm)

4.1 ± 6.6 (−5.8 to 19.7)

6.0 ± 7.0 (−3.2 to 21.1)

0.362

  1. V-COR, vertical center of rotation; H-COR, horizontal center of rotation; ALA, abductor level arm; LLD, leg length discrepancy