Table 3 Summary of the measured inlet and outlet angles for the preoperative CT, intraoperative fluoroscopic views, and postoperative CT scan for each patient

From: Correlating preoperative imaging with intraoperative fluoroscopy in iliosacral screw placement

Patient

Preop CT inlet

Fluoro inlet

Postop CT inlet

Preop CT outlet

Fluoro outlet

Postop CT outlet

1

13

22

15

47

40

40

2

25

30

23

41

50

45

3

19

20

22

47

45

47

4

37

32

31

44

42

44

5

23

20

23

39

40

42

6

9

30

8

44

43

44

7

18

26

19

59

52

56

8

19

21

20

45

40

44

9

7

12

8

46

40

42

10

22

30

25

38

42

40

11

10

19

8

46

41

47

12

27

31

25

42

42

39

13

32

28

28

47

50

52

14

21

21

18

30

29

33

15

17

20

16

45

40

40

16

24

30

23

43

51

44

17

12

18

9

43

42

41

18

21

27

20

41

45

46

19

10

15

8

56

51

55

20

22

30

21

42

39

44

21

21

27

21

41

40

43

22

28

29

25

30

35

34

23

32

38

31

42

40

44

24

24

23

19

30

38

31

Average

20.5

24.9

19.4

42.8

42.4

43.2

Range

7–37

12–38

8–31

30–59

29–52

31–56

  1. The average and range of values is listed for each measurement