Table 2 Posterior displacement for the transsacral group

From: Supplemental S1 fixation for type C pelvic ring injuries: biomechanical study of a long iliosacral versus a transsacral screw

Number of cycles

Displacement (in mm)

Minimum

Maximum

Mean

Standard deviation

P value*

25,000

6.2

16.4

10.6

3.9

50,000

6.6

17.7

11.3

4.3

0.025

75,000

6.9

18.3

11.5

4.4

0.040

100,000

7.1

18.7

12.3

4.5

0.025

  1. * Freidman test