Skip to main content

Official Journal of the Italian Society of Orthopaedics and Traumatology

Table 3 Improvements in grip strength, range of motion, and sensibility

From: Results of the Max Page muscle sliding operation for the treatment of Volkmann’s ischemic contracture of the forearm

S. no.

Hand grip (%)

Dexterity score

Sensibility score

Pre-op

Post-op

Pre-op

Post-op

Pre-op

Post-op

1

17

84

5

11

2

2

2

15

80

6

12

2

2

3

5

80

5

12

2

2

4

0

63

3

9

1

2

5

0

83

3

8

2

2

6

0

20

1

4

1

1

7

0

70

3

9

2

2

8

0

65

2

7

2

2

9

18

79

5

11

2

2

10

6

75

7

12

2

2

11

8

85

6

11

2

2

12

10

78

4

8

2

2

13

0

65

5

10

1

2

14

8

78

7

12

2

2

15

12

85

5

12

2

2

16

0

85

6

10

2

2

17

0

84

5

11

1

2

18

16

80

5

10

2

2

19

20

87.5

5

12

1

2

Mean ± SD

7.10 ± 7.33

75.07 ± 15.24

4.63 ± 1.60

10.05 ± 2.14

1.73 ± 0.45

1.94 ± 0.22

Paired t values

 

21.60

 

22.07

 

2.19

d.f.

 

18

 

18

 

18

p values

 

<0.001

 

<0.001

 

<0.05